Impacted cards: 10N9874, 10N9879, 10N9879
Impacted range: cards were shipped to Nikki, got a Supplier Problem Log from Nikki.
Action required by Nikki: Need not rework WIP, DOA, RMA, and shipped cards.
Action taken in Wistron: issue ECR0800201 to correct the BOM. These parts/locations (270pcs) were manually modified in SMT program and SOP for the urgent case because the EC not take effective.
Error found on 1/10
Problem: 49G3548AA was missed in the BOM 46K6537(Kaleri 2W).
Impacted cards:46K6537
Impacted range: This problem was found before we start a new build. No impact on built cards.
Action required by Nikki: No.
Action taken in Wistron: issue R0800252 to correct the BOM.
Error found on 1/14
The problem is: we mis-place a wrong part on the indicated location.
Impacted cards:10N9874,10N9869,10N9879
Impacted range: Cards were shipped to Nikki.
Action required by Nikki: Rework all WIP, RMA, DOA. Nikki requested 40pcs of 77P1237AA for their reworking job.
Action taken in Wistron: issue ECR0800201 to correct the BOM. Rework all WIP.(total 77pcs)
Error found on 1/17
Problem: 30F8247AA was placed at incorrect location.
Wistron P/N Wrong Loc Correct Loc Qty
*************************************
30F8247AA R1050 R1614 1pcs
Impacted cards: 46K6542
Impacted range: The build was started. Need to rework WIP.
Action required by Nikki: No. No cards was shipped to Nikki.
Action taken in Wistron: issue R0800252 to correct the BOM. Rework all WIP.(total 3pcs)